Solid Phase Extraction System

Prominent & Leading from Thane, we offer spe vacuum manifold system, spe vacuum manifold, vacuum manifold for 96 well plates, positive pressure solid phase extraction equipment, solid phase extraction unit and 96 well plate positive pressure processor.

SPE Vacuum Manifold System

Request Callback

₹ 62500 / Piece Get Latest Price

Product Brochure
MaterialMS
Frequency50 hz
Voltage240 V
TypeManifold System
ApplicationIndustrial
SPE Vacuum Manifold System Vacuum SPE Manifold, Solid phase extraction SPE is a chromatographic technique used to prepare samples for subsequent analysis by removing interfering substances that may be present. The general procedure includes sorbent activation, loading, washing and eluting. This is done either by retaining the substance of interest and washing off everything else or by retaining the interfering substances and eluting the product of interest. The vacuum SPE devices are designed to concentrate or isolate analytes from complex sample matrices. It allows processing of extraction columns with high sample throughput at minimal expense. Solvents and samples are aspirated through the columns by a vacuum of 0-20 inches Hg. Eluates are collected in tubes positioned in a removable rack inside the manifold. The 12-ports and 24-ports manifold accommodate up to 12 and 24 columns, respectively.

 

Application:

  • Multiple sample processing saves time and money.
  • Female Luer inlets fit all male Luer tipped SPE tubes and cartridges.
  • Compatible with standard Luer-tipped SPE and filtration columns.
  • Glass chamber allows easy visual monitoring.
  • Adjustable racks accommodate a variety of test tubes, vials and flasks.
  • Available in 12 and 24-position for standard tubes

Specifications:

Glass chamber

Vacuum gauge

12 position cover with Luer Fittings

12 Retaining Clips

Gasket

4 Supports

12 Individual Flow Control Stopcocks

12 Luer Plugs

3 Posts

Valve Assemble

6 Shelves

Waster container

12 Guide needles

 

 

24 Position SPE Manifold System:
 

Glass chamber

Vacuum gauge

24 position cover with Luer Fittings

24 Retaining Clips

Gasket

4 Supports

24 Individual Flow Control Stopcocks

24 Luer Plugs

3 Posts

Valve Assemble

4 Shelves

24 Guide needles

SPE Vacuum Manifold

Request Callback

₹ 68500 / Piece Get Latest Price

Product Brochure
Position12 or 24
ChamberAcrylic or Plexiglass
MaterialMs
ShapeRectangle
PowerElectric
SPE Vacuum Manifold
SPE Vacuum Manifold System Vacuum SPE Manifold, Solid phase extraction SPE is a chromatographic technique used to prepare samples for subsequent analysis by removing interfering substances that may be present. The general procedure includes sorbent activation, loading, washing and eluting. This is done either by retaining the substance of interest and washing off everything else or by retaining the interfering substances and eluting the product of interest. The vacuum SPE devices are designed to concentrate or isolate analytes from complex sample matrices. It allows processing of extraction columns with high sample throughput at minimal expense. Solvents and samples are aspirated through the columns by a vacuum of 0-20 inches Hg. Eluates are collected in tubes positioned in a removable rack inside the manifold. The 12-ports and 24-ports manifold accommodate up to 12 and 24 columns, respectively.

 

Application:

  • Multiple sample processing saves time and money.
  • Female Luer inlets fit all male Luer tipped SPE tubes and cartridges.
  • Compatible with standard Luer-tipped SPE and filtration columns.
  • Glass chamber allows easy visual monitoring.
  • Adjustable racks accommodate a variety of test tubes, vials and flasks.
  • Available in 12 and 24-position for standard tubes
VACUUM MANIFOLD SYSTEM
For Solid Phase Extraction

Ø Rectangular Acrylic Cabinet; 2 Sizes Available:
Ø Small For Up To 12 Columns Cartridges
Ø Large For Up To 12 Lv Columns Or Up To 24 Cartridges (Depending On Lid)
Ø Polypropylene Lid
Ø Vacuum Gauge For Pressure Reading
Ø Control Valve For Adjustment Of Vacuum
Ø Replaceable Valves For Vacuum Control Of Individual Spe Columns
Ø Variable Rack With Exchangeable Partitions, Which Accept A Wide Variety Of Vessels Like Test Tubes, Measuring Flasks, Scintillation Vials, Autosampler Vials, Plastic Vials Etc.
Ø 20um Columns With 5-10 Ml Sample Reservoir For Medium Size Samples
Ø Polypropylene Sample Reservoir (5 Or 50 Ml Available)
Ø Adapter For Sample Reservoirs
Ø Spe Manifold Tubing Adapters

Vacuum Manifold For 96 Well Plates

Request Callback

₹ 54500 / Piece Get Latest Price

MaterialMS
Length8 Inch
Thickness3 mm
ShapeRectangle
TypeWell Plates
96 WELL VACUUM MANIFOLD
  • For use with 96 well Purification kits
  • Includes Single Column Adapter Plate
  • Constructed of cast Acrylic

The IBI 96 well Vacuum manifold is designed for use with high throughput 96 well plate nucleic acid purification products and single prep columns.

Unit is constructed ofcast acrylic for easy care and cleaning and comes complete with Waste Tray, Collection Plate Spacer and Single Column Adapter plate to accommodate multiple extractions of single column preps.

Unit also comes with vacuum valve and release valve.

The design of the upper portion of the manifold reduces cross contamination between wells allowing for the most effective extraction and purification of plasmid DNA,

Genomic DNA, Viral DNA, Total RNA and PCR products.

Material: Manifold - Cast Acrylic -

 

Dimensions: 17cm(L) x 12cm(W) x 8cm(H) Operation: In-house vacuum or equivalent pump Max Vacuum: Approx. 71cm Hg (28 in Hg) (-13.7 psi) Unit comes with vacuum valve and release valve.

Positive Pressure Solid Phase Extraction Equipment

Request Callback

₹ 185000 / Piece Get Latest Price

Product Brochure
Power SourceNitrogen Gas
MaterialPTFE
Type Of InstrumentsPlasma
ColorSPE Positive Pressure Manifold
Model NumberLCMSMS
Size/Dimension48
Positive Pressure Solid Phase Extraction:
SPE cartridges are used in a broad variety of labs – hospitals and toxicology service labs performing medicolegal drug testing, CRO’s for bio analytical/bio equivalence studies and food contaminants testing labs. The manual process is very labour intensive and makes operators prone to RSI. Human errors lead to lower TAT, more repeat tests and therefore higher costs and overall lowered lab efficiency. Moreover, operators are exposed to hazardous solvents posing health risks. 144 positive pressure processor for solid phase extraction columns96 positive pressure processor for solid phase extraction columns48 positive pressure processor for solid phase extraction columns Uniform flow across all columns High end positive pressure manifold Higher pressure. Up to 80 PSI More effective on difficult matrices such as oral fluid, viscous urines or whole blood Active drying of the SPE bed to facilitate complete dryness

Features:
  • Decreased variation in column processing, improved analyte recovery reproducibility Formatted
  • for SPE ware microparticulate sorbents
  • Vacuum manifolds max out at 1 Atmosphere
  • Further improves ruggedness of methods and produces more reproducible methods
  • Increased flexibility in method optimization
  • Manifold Available in 48, 96 place formats
  • Reduced run to run variability, reduced operator variability More reproducible methods with reduced risk of errors
  • Programmable pressure profiles
  • Electronic, programmable flow control

Solid Phase Extraction Unit

Request Callback

₹ 265000 / Piece Get Latest Price

PhaseTWO
Power SourceElectric
Frequency40hz
Materialms
Automation GradeSemi-Automatic
Voltage240 V
The Athena System 96 allows for gas pressures up to the supplied line pressure (typically 60-75 psi.), thus supplying greater motive force for viscous sample flow. Adjusting the pressure up or down, produces a column flow response that is smooth and immediate. The optional heated manifold provides for rapid and thorough column drying, resulting in cleaner extracts and superior specificity when working with non-polar elution solvents.
In contrast, the System 96 uses unique, restricted-flow gas ports. These ports create superior flow control such that even if 95 out of 96 wells are empty, dry, or wet, the remaining single well will receive normal pressure to allow facile processing.

Features and Advantages:
  • Highly uniform flow from sample to sample for SPE, Protein Precipitation and Supported Liquid Extraction
  • Improved reproducibility, accuracy and extraction efficiency, even with viscous samples
  • Parallel processing for increased sample throughput
  • Easy to set-up and use with just a gas source
  • Universal designs accommodate all 96 well plates, or 1 mL, 3 mL and 6 mL SPE columns
  • Built-in safety features ensure ease of use and safe operation

 

Manufacturer of Positive Pressure Manifolds Modular Rack System:

By using stackable collection racks and extraction racks on the Athena PRESSURE 48 96 manifold, many combinations are possible to accommodate varying methodologies. Racks only fit the system in one direction, ensuring consistent processing throughout.

96 Well Plate Positive Pressure Processor

Request Callback

₹ 205000 / Piece Get Latest Price

BrandAthena
FlowMax 10 Lpm
Pressure0-4 Bar Gauge
MOCSS316
96 wellPlate SPE
GasNitrogen
96 well plate Positive Pressure Processor 
The self-adjusting upper manifold of the Athena PPP 96 well plate manifold is compatible with all 96 well plate formats in addition to the popular 1 mL and 2 mL modular array well formats without the need to purchase supplementary gaskets. Biotage collection plates are recommended for the most consistent and reliable results.

Features and Advantages
  • Highly uniform flow from sample to sample for SPE, Protein Precipitation and Supported Liquid Extraction 
  • Improved reproducibility, accuracy and extraction efficiency, even with viscous samples
  • Parallel processing for increased sample throughput
  • Easy to set-up and use with just a gas source
  • Universal designs accommodate all 96 well plates, or 1 mL, 3 mL and 6 mL SPE columns Built-in safety features ensure ease of use and safe operation
Athena  provides a wide range of 96 well plate positive pressure processors. These state of the art machines offer users complete control in running Solid Phase Extraction experiments by using different sources of dry, pressurized gases. Unlike vacuum manifolds, each of the ports in the processor are restricted in order to maintain constant pressure, regardless of whether all the other well plate positions are filled or not

Both single or double 96-well plate format, and 48, 96, or 144 cartridge format

For plate format, it fits 1cc, 2cc per well plate as well as microelute plate

Using dry pressurized air, nitrogen or other inert gases

Positive Pressure Manifold

Request Callback

₹ 287000 / Piece Get Latest Price

Product Brochure
MaterialMS
Voltage240 V
Frequence50 hz
TypePressure Manifold
BrandAthena
Positive Pressure Manifold:
  • 48 Positive Pressure Manifold SPE
  • 96 Positive Pressure Manifold SPE
  • 144 Positive Pressure Maniold

Positive Pressure Manifolds for simple Sample Preparation96 Positive Pressure Manifolds Athena System 96 for Positive Pressure SPE provides uniformity of flow - something that is not achievable with conventional vacuum manifolds.
The System 96 offers an efficient solution to viscous samples. Vacuum manifolds often cannot provide adequate processing power, since the maximum pressure is limited to less than atmospheric pressure (approx. 15 psi). 96 well plates, 1 mL 3 mL and 6 mL column formats. The systems utilize a consistent, uniform flow of positive pressure to move both low and high viscosity liquids through SPE plates and columns. The Athena System 96 allows for gas pressures up to the supplied line pressure (typically 60-75 psi.), thus supplying greater motive force for viscous sample flow. Adjusting the pressure up or down, produces a column flow response that is smooth and immediate. The optional heated manifold provides for rapid and thorough column drying, resulting in cleaner extracts and superior specificity when working with non-polar elution solvents.
In contrast, the System 96 uses unique, restricted-flow gas ports. These ports create superior flow control such that even if 95 out of 96 wells are empty, dry, or wet, the remaining single well will receive normal pressure to allow facile processing.

Features and Advantages
  • Highly uniform flow from sample to sample for SPE, Protein Precipitation and Supported Liquid Extraction
  • Improved reproducibility, accuracy and extraction efficiency, even with viscous samples
  • Parallel processing for increased sample throughput
  • Easy to set-up and use with just a gas source
  • Universal designs accommodate all 96 well plates, or 1 mL, 3 mL and 6 mL SPE columns
  • Built-in safety features ensure ease of use and safe operation

 

Manufacturer of Positive Pressure Manifolds Modular Rack System:
  • By using stackable collection racks and extraction racks on the Athena PRESSURE+ 48 96 manifold, many combinations are possible to accommodate varying methodologies. Racks only fit the system in one direction, ensuring consistent processing throughout. Manufacturer of Positive Pressure Manifold System Indian Positive Pressure Manifold

144 Positive Pressure Manifold

Request Callback

₹ 455000 / Piece Get Latest Price

Product Brochure
ApplicationLaboratory Use
ModelSPE144
MaterialSS
Dimensions96x 12x75 Cm
Weight20 kgs
144 Positive Pressure Manifold
Solid Phase Extration
SPE 144
Positive pressure processor
Specification:

  • SPE sizes can be switched between each size by changing the adapter plate
  • Dual setting allow users to set different pressure for extraction and column drying.
  • 2 Collection Rack for specific test tubes size
  • Includes waste reservoir with stopcock assembly to allow for direct drainage of waste.
  • Single switch raises and lowers the sample racks and creates an airtight seal. 
  • Using manual positive pressure manifolds with flow restriction

 

Features Advantages

  • Uniform flow across all columns
  • High end positive pressure manifold
  • Higher pressure. Up to 80 PSI
  • More effective on difficult matrices such as oral fluid, viscous urines or whole blood
  • Active drying of the SPE bed to facilitate complete dryness
  • Programmable pressure profiles
  • Electronic, programmable flow control

Benefits

  • Decreased variation in column processing, improved analyte recovery reproducibility Formatted
  • for Athena SPE ware micro particulate sorbents
  • Vacuum manifolds max out at 1 Atmosphere
  • Further improves ruggedness of methods and produces more reproducible methods
  • Increased flexibility in method optimization.
  • Reduced run to run variability, reduced operator variability
  • More reproducible methods with reduced risk of errors.


Export : USA, Europe, Africa, Canada, Germany, France, Italy, UK, NY, NJ US, Turkey, Egypt,

 

Automated Solid Phase Extration

X

Contact Us

Milan Salunke (Director)
Athena Instruments Pvt. Ltd.
1 ST Floor, Shop No. 141, Lodha'S Boulevard Mall, Near Eastern Express Highway
Thane - 400601, Maharashtra, India

Get Directions
Send Email
Share: